Begin Part Validation | Aeccc_CB_STM_CATCHBASINStructure_Metric

Begin Part Family self validation test
ERROR: Required Parameter not found: Material
ERROR: Required Parameter not found: Cover
ERROR: Required Parameter not found: CB-TYPE
OK: Part Domain parameter validated -- Structure_Domain
ERROR: Part Type parameter not validated
OK: Part Subtype parameter validated -- Undefined
ERROR: Part Description parameter not found
OK: Part Name parameter validated -- Aeccc_CB_STM_CATCHBASINStructure_Metric
OK: Part Size Name parameter found
ERROR: Duplicated ID found in this or other local catalog, may be replaced with --> AD3E05AA-EE40-4BCD-BC90-33FBEAA1BCD7
OK: Data Version parameter validated, version = 2.0
OK: Sample Expanded Table row successfully created
 
Begin Calc Usage Validation
OK: Calc Parameter PrtSN uses Context=Catalog_PartSizeName
OK: Calc Parameter LenA1 uses Context=Geometry_Distance2D
OK: Calc Parameter LenA2 uses Context=Geometry_Distance2D
OK: Calc Parameter LenB1 uses Context=Geometry_Distance3D
OK: Calc Parameter SBSH uses Context=StructHeight
OK: Calc Parameter SBSL uses Context=StructLength
OK: Calc Parameter SBSW uses Context=StructWidth
 
ERROR: Table Data Validation Failed | C:\_City of Barrie - CAD Standard ver2.0 (2017)\TESTING - 2017\2017 Pipes Catalog\Metric Structures\CB\Aeccc_CB_STM_CATCHBASINStructure_Metric.xml

ERROR: Part Validation Failed | CB\Aeccc_CB_STM_CATCHBASINStructure_Metric.xml